Products |
Hybrid controllers for 300W, 400W, 600W wind turbines (12V/24V)
Technical Parameters |
||||
Model |
FS03-12 |
FS04-12 |
FS06-24 |
|
Wind Turbine Input |
|
|||
Rated input power |
300W |
400W |
600W |
|
Rated input voltage |
14Vdc |
14Vdc |
28Vdc |
|
Input voltage range |
0~16Vdc |
0~16Vdc |
0~32Vdc |
|
Rated input current |
25Adc |
34Adc |
25Adc |
|
Brake by hand |
Press button “Enter” “Esc” at the same time to unload completely. Then recover by hand. |
|||
Brake by over current |
25A(factory default,0~25A settable)Unload completely when reached the set current, and recover automatically after working 10mins. |
34A(factory default,0~34A settable)Unload completely when reached the set current, and recover automatically after working 10mins. |
25A(factory default,0~25A settable)Unload completely when reached the set current, and recover automatically after working 10mins. |
|
Brake by overvoltage |
Refer to “output overvoltage” control |
|||
Brake by over wind speed(optional) |
14m/s(0-30m/s settable),Unload completely when reached the set wind speed, and recover automatically after working 10mins. |
|||
Brake by over rotational Speed(optional) |
500r/min(factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
|||
PV Input Parameters |
|
|||
Rated input power |
150W |
300W |
||
Max. open circuit voltage |
24V |
48V |
||
Rated input current |
13A |
|||
Reversed connection protection |
YES |
|||
Charge Parameters |
|
|||
Rated battery voltage |
12V |
24V |
||
Temperature compensation function(optional) |
-3mV/℃/2V |
|||
Output Parameters |
|
|||
Rated output voltage |
12V |
24V |
||
Start unload voltage |
13.5V(factory default,11Vdc~16Vdc settable) |
27V(factory default,22Vdc~32Vdc settable) |
||
Complete unload voltage |
14.5V(factory default, add 1V to the start unload voltage) |
29V(factory default, add 2V to the start unload voltage) |
||
Max. Output current |
25A |
34A |
25A |
|
DC load output |
|
|||
Output loops |
2 loops |
|||
Output control mode |
Both 2 loops could be set in 7 modes, such as light control on&off, light control on and time control off. |
|||
Output voltage range |
10.8V~16V |
21.6V~32V |
||
Undervoltage recovery point |
Refer to "rated battery voltage" |
|||
Rated output current |
10A/each loop |
|||
Overload protection |
120% rated DC output -1min,150% rated DC output -10s |
|||
Short circuit protection |
200% rated DC output, instant protection |
|||
General Parameters |
|
|||
Rectifier mode |
Uncontrolled rectifier |
|||
Display mode |
LCD |
|||
Display information |
Battery voltage, wind turbine voltage/current/ power, PV power/voltage/current, light control-on voltage, light control-off voltage, time control duration, load current and so on. |
|||
Monitoring mode(optional) |
RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee |
|||
Monitoring Contents |
Real-time display: Battery voltage, wind turbine voltage/current/ power, PV power/voltage/current, wind power generation capacity, solar power generation capacity, Battery status, wind turbine status, day and night, DC overload, DC load short circuit, and so on. |
|||
Parameter setting: Output overvoltage point, wind turbine over current point, wind turbine start voltage, DC load overvoltage/undervoltage |
||||
Lightning protection |
YES |
|||
Conversion efficiency |
≥95% |
|||
Static loss |
<0.5W |
|||
Environment temperature |
-20℃~+40℃ |
|||
Humidity |
5%~95%,No condensing |
|||
Noise |
≤65dB |
|||
Cooling mode |
Natural cooling |
|||
Installation mode |
Wall-mounted |
|||
Cover protection class |
IP52 |
|||
Product dimension(W*H*D) |
150×143×83mm |
|||
Product net weight |
1.8kg |
|||
Note: the listed specs are just for your reference |
Hybrid controller for 600W48V wind turbine
Model |
FS06-48 |
|
Wind Turbine Input |
|
|
Rated input power |
600W |
|
Rated input voltage |
56Vdc |
|
Input voltage range |
0~64Vdc |
|
Rated input current |
13Adc |
|
Brake by hand |
Press button “Enter” “Esc” at the same time to unload completely. Then recover by hand. |
|
Brake by over current |
13A (factory default,0~13A settable)Unload completely when reached the set current, and recover automatically after working 10mins. |
|
Brake by overvoltage |
Refer to “output overvoltage” control |
|
Brake by over wind speed (optional) |
14m/s (0-30m/s settable), Unload completely when reached the set wind speed, and recover automatically after working 10mins. |
|
Brake by over rotational Speed (optional) |
500 r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
|
PV Input Parameters |
|
|
Rated input power |
300W |
|
Max. open circuit voltage |
96V |
|
Rated input current |
7A |
|
Reversed connection protection |
YES |
|
Charge Parameters |
|
|
Rated battery voltage |
48V |
|
Temperature compensation function (optional) |
-3mV/℃/2V |
|
Output Parameters |
|
|
Rated output voltage |
48V |
|
Output overvoltage point |
58V (factory default,44Vdc~64Vdc settable) |
|
Output overvoltage recovery point |
52.8V (factory default, reduce 5.2V from the output overvoltage point) |
|
Max. Output current |
13A |
|
DC Load Output(Optional) |
|
|
Output loops |
2 loops |
|
Output control mode |
Both 2 loops could be set in 7 modes, such as light control on&off, light control on and time control off. |
|
Output voltage range |
43.2V~64V |
|
Undervoltage recovery point |
Refer to "rated battery voltage" |
|
Rated output current |
10A/each loop |
|
Overload protection |
120% rated DC output -1min,150% rated DC output -10s |
|
Short circuit protection |
200% rated DC output, instant protection |
|
General Parameters |
|
|
Rectifier mode |
Uncontrolled rectifier |
|
Display mode |
LCD |
|
Display information |
Battery voltage, wind turbine voltage/current/ power, PV power/voltage/current, light control-on voltage, light control-off voltage, time control duration, load current and so on. |
|
Monitoring mode (optional) |
RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee |
|
Monitoring Contents |
Real-time display: Battery voltage, wind turbine voltage/current/ power, PV power/voltage/current, wind power generation capacity, solar power generation capacity, Battery status, wind turbine status, day and night, DC overload, DC load short circuit, and so on. |
|
Parameter setting:Output overvoltage point, wind turbine over current point, wind turbine start voltage, DC load overvoltage/undervoltage |
||
Lightning protection |
YES |
|
Conversion efficiency |
≥95% |
|
Static loss |
<0.5W |
|
Environment temperature |
-20℃~+40℃ |
|
Humidity |
5%~95%,No condensing |
|
Noise |
≤65dB |
|
Cooling mode |
Natural cooling |
|
Installation mode |
Wall-mounted |
|
Cover protection class |
IP52 |
|
Product dimension (W*H*D) |
150×205×82mm |
|
Product net weight |
2.8kg |
|
Note: the listed specs are just for your reference |
Hybrid controller for 1000W wind turbine (48V/24V)
Technical Parameters
Model |
FS10-24 |
FS10-48 |
Wind Turbine Input |
||
Rated input power |
1kW |
|
Rated input voltage |
24Vdc |
48Vdc |
Input voltage range |
0~32Vdc |
0~64Vdc |
Rated input current |
42A |
21A |
Brake by hand |
Keep press the button for 5s to unload completely, and then recover by hand. |
|
Switch “ON” the brake switch |
||
Brake by over current |
42A (factory default, 0~42A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
21A (factory default, 0~21A settable) unload completely when reached the set current, and recover automatically after working 10mins. |
Brake by overvoltage |
Refer to “output overvoltage” control |
|
Brake by over wind speed (optional) |
18m/s (0-30m/s settable), unload completely when reached the set wind speed, and recover automatically after working 10mins. |
|
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
|
PV Input |
||
Rated input power |
300W |
|
Max. Open circuit voltage |
48Vdc |
96Vdc |
Rated input current |
13A |
7A |
Reversed connection protection |
YES |
YES |
Charge Parameters |
||
Rated battery voltage |
24Vdc |
48Vdc |
Temperature compensation function (optional) |
-3mV/℃/2V |
|
Output Parameters |
||
Rated output voltage |
24Vdc |
48Vdc |
Output overvoltage point |
29Vdc |
58Vdc |
output overvoltage recovery point |
it will recover automatically once it is lower than output overvoltage point. |
|
Max. Output current |
42A |
21A |
General Parameters |
||
Rectifier mode |
Uncontrolled rectifier |
|
Display mode |
LCD |
|
Display information |
DC output voltage, wind voltage/current/power, battery voltage, PV voltage/current/power. |
|
Monitoring mode (optional) |
RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee |
|
Monitoring Contents |
DC output voltage, wind voltage/current/power, battery voltage, PV voltage/current/power. |
|
parameter setting: output overvoltage point, wind overcurrent point and manual brake |
||
Lightning protection |
YES |
|
Conversion efficiency |
≥95% |
|
Static loss |
<2W |
<1W |
Ambient temperature |
-20℃~+40℃ |
|
Humidity |
0~90%, No condensing |
|
Noise |
≤65dB |
|
Cooling mode |
Natural cooling |
|
Installation mode |
Wall-mounted |
|
Cover protection class |
IP20 |
|
Product dimension (W*H*D) |
420×440×175 mm |
|
Product net weight |
10kG |
Contact Information |
Add:(9-12-10), 16, Caihong South Road, Yinzhou District, Ningbo, 315803, China Sales: +86 13777255563 +86-574-87881781 |